Peak Lcr40: Top-notch Specifications, Comprehensive Comparisons, And Trusted Buying Sources

Peak LCR40 Information

The Peak LCR40 is an automatic passive component analyzer that measures the inductance, capacitance, and resistance of inductors, capacitors, and resistors. It is a handheld device that is easy to use and provides accurate readings.

Introduction

The LCR40 is a popular choice for hobbyists, technicians, and engineers who need to test passive components. It is a versatile tool that can be used to measure a wide range of components, including:

  • Inductors: from 1 µH to 2 H Image of Inductors LCR40
  • Capacitors: from 1 pF to 100,000 µF Image of Capacitors LCR40
  • Resistors: from 1 Ω to 2 MΩ Image of Resistors LCR40

The LCR40 also has a number of features that make it a valuable tool for troubleshooting electronic circuits. These features include:

  • Automatic component identification: The LCR40 automatically identifies the type of component being tested and displays the results on the screen.
  • Automatic test frequency selection: The LCR40 automatically selects the best test frequency for the component being tested, ensuring accurate readings.
  • Hold function: The hold function allows you to freeze the readings on the screen, making it easier to take measurements.
  • Datalogging: The LCR40 can store up to 1000 measurements, making it easy to track changes in component values over time.

Specifications

The following table summarizes the specifications of the Peak LCR40:

SpecificationValue
Inductance range1 µH to 2 H
Capacitance range1 pF to 100,000 µF
Resistance range1 Ω to 2 MΩ
Test frequenciesDC, 1 kHz, 15 kHz, and 200 kHz
Resolution0.8 µH, 0.5 pF, and 0.1 Ω
Accuracy± (1% + 2 digits)
Dimensions103 x 70 x 20 mm
Weight120 g

Features

In addition to the features mentioned above, the Peak LCR40 also has a number of other features, including:

  • Backlit display: The display is backlit, making it easy to read in low-light conditions.
  • Audible continuity test: The LCR40 has an audible continuity test that makes it easy to check for broken or open components.
  • Beeper: The LCR40 has a beeper that can be used to signal the start and end of a test.
  • Battery level indicator: The LCR40 has a battery level indicator that shows how much power is left in the battery.

What's in the box

The Peak LCR40 comes in a box that includes the following items:

  • LCR40 meter
  • 2mm test leads
  • Hook probes
  • User manual
  • Spare battery

Conclusion

The Peak LCR40 is a versatile and easy-to-use passive component analyzer that is ideal for hobbyists, technicians, and engineers. It is a valuable tool for troubleshooting electronic circuits and measuring the values of inductors, capacitors, and resistors.

Peak LCR40 Compare with Similar Item

a table comparing the Peak LCR40 to some similar items:

FeaturePeak LCR40Atlas ESR70Peak LCR45
Price$139.99$119.00$159.69
Operating frequency range10 Hz to 1 MHz10 Hz to 1 MHz10 Hz to 1 MHz
Measurement accuracy±(0.5%+2)±(0.4%+2)±(0.3%+2)
Resolution0.01 mΩ0.01 mΩ0.001 mΩ
Display3.5" color TFT LCD2.4" monochrome LCD3.5" color TFT LCD
Dimensions103 x 70 x 20 mm100 x 68 x 30 mm103 x 70 x 20 mm
Weight150 g120 g150 g
Battery life20 hours20 hours20 hours

As you can see, the Peak LCR40 is a mid-range LCR meter with good accuracy and resolution. It is a good choice for hobbyists and professionals who need to measure a variety of passive components. The Atlas ESR70 is a less expensive option with slightly lower accuracy and resolution. The Peak LCR45 is a more expensive option with higher accuracy and resolution.

Here is a summary of the key differences between the three meters:

FeaturePeak LCR40Atlas ESR70Peak LCR45
Price$139.99$119.00$159.69
Accuracy±(0.5%+2)±(0.4%+2)±(0.3%+2)
Resolution0.01 mΩ0.01 mΩ0.001 mΩ
Display3.5" color TFT LCD2.4" monochrome LCD3.5" color TFT LCD
Dimensions103 x 70 x 20 mm100 x 68 x 30 mm103 x 70 x 20 mm
Weight150 g120 g150 g
Battery life20 hours20 hours20 hours

Ultimately, the best LCR meter for you will depend on your specific needs and budget. If you need a high-accuracy meter with a color display, then the Peak LCR45 is a good option. If you are on a tight budget, then the Atlas ESR70 is a good choice. And if you are looking for a basic meter with good accuracy and resolution, then the Peak LCR40 is a good option.

Peak LCR40 Pros/Cons and My Thought

a 500-word summary of the Peak LCR40, including pros, cons, user reviews, and my thoughts:

The Peak LCR40 is a high-quality, versatile LCR meter that is well-suited for a variety of applications. It features a wide frequency range, accurate measurements, and a user-friendly interface.

Pros:

  • Wide frequency range: The Peak LCR40 can measure inductance, capacitance, and resistance from 100 Hz to 1 MHz. This makes it a versatile tool for a variety of applications, including electronics troubleshooting, component testing, and quality control.
  • Accurate measurements: The Peak LCR40 is known for its accurate measurements. It has a typical accuracy of ±0.5% for inductance and capacitance, and ±1% for resistance.
  • User-friendly interface: The Peak LCR40 has a user-friendly interface that makes it easy to use. The large LCD display shows clear, easy-to-read readings. The menu system is also easy to navigate.

Cons:

  • Price: The Peak LCR40 is a bit more expensive than some other LCR meters on the market. However, its accuracy and versatility make it a good value for the price.
  • Size: The Peak LCR40 is a bit larger than some other LCR meters. This may make it less portable for some users.

User reviews:

Overall, user reviews of the Peak LCR40 are positive. Users praise its accuracy, versatility, and user-friendly interface. Some users have also commented on its durability.

My thoughts:

I think the Peak LCR40 is a great LCR meter. It is accurate, versatile, and user-friendly. I would recommend it to anyone who needs a high-quality LCR meter for a variety of applications.

Here are some additional thoughts on the Peak LCR40:

  • The Peak LCR40 is a good value for the price. It is accurate, versatile, and user-friendly.
  • The Peak LCR40 is a bit larger than some other LCR meters. This may make it less portable for some users.
  • The Peak LCR40 is a good choice for electronics troubleshooting, component testing, and quality control.

I hope this summary is helpful. Please let me know if you have any other questions.

Peak LCR40 Where To Buy

Sure. Here are some places where you can buy Peak LCR40 and spare parts:

  • Direct: You can buy Peak LCR40 and spare parts directly from the Peak website. They have a wide selection of parts available, and you can usually find what you need at a good price. Image of Peak LCR40 direct website
  • Walmart: Walmart is another good option for buying Peak LCR40 and spare parts. They usually have a good selection of parts in stock, and their prices are competitive. Image of Peak LCR40 Walmart website
  • Amazon: Amazon is a great place to find just about anything, including Peak LCR40 and spare parts. They have a huge selection of parts available, and you can usually find what you need at a good price. Image of Peak LCR40 Amazon website
  • Best Buy: Best Buy is a good option for buying Peak LCR40 if you need it quickly. They usually have a good selection of parts in stock, and you can pick up your order in-store the same day. Image of Peak LCR40 Best Buy website
  • Lowes: Lowes is another good option for buying Peak LCR40 if you need it quickly. They usually have a good selection of parts in stock, and you can pick up your order in-store the same day. Image of Peak LCR40 Lowes website
  • eBay: eBay is a good option for finding rare or discontinued Peak LCR40 and spare parts. You can often find good deals on parts on eBay, but be sure to do your research to make sure you are getting a genuine part. Image of Peak LCR40 eBay website

I hope this helps!

Peak LCR40 Problems and Solutions

some common issues and problems with the Peak LCR40, along with solutions from experts:

  • The meter does not turn on.
    • Solution: Check the power supply to make sure it is plugged in and turned on. If the power supply is good, then the meter may be defective.
  • The meter displays incorrect readings.
    • Solution: Make sure the meter is properly calibrated. If the meter is calibrated correctly, then the problem may be with the probes. Try using different probes to see if that fixes the problem.
  • The meter is not measuring capacitance correctly.
    • Solution: Make sure the meter is set to the correct capacitance range. If the meter is set to the correct range, then the problem may be with the capacitors themselves. Try measuring a known good capacitor to see if the meter is giving the correct reading.
  • The meter is not measuring inductance correctly.
    • Solution: Make sure the meter is set to the correct inductance range. If the meter is set to the correct range, then the problem may be with the inductors themselves. Try measuring a known good inductor to see if the meter is giving the correct reading.

Here are some additional tips from experts for troubleshooting Peak LCR40 problems:

  • Check the connections. Make sure that all of the connections to the meter are secure. Loose or damaged connections can cause incorrect readings.
  • Clean the probes. Over time, the probes on the meter can become dirty or corroded. This can also cause incorrect readings. Clean the probes with a mild solvent and a soft cloth.
  • Update the firmware. The firmware on the Peak LCR40 is periodically updated with bug fixes and performance improvements. Make sure that your meter is running the latest firmware.

If you are still having problems with your Peak LCR40 after following these tips, you can contact Peak Electronics customer support for assistance.

Peak LCR40 Manual

Peak LCR40 Passive Component Analyser

Safety Information

  • Do not use the LCR40 in a flammable or explosive atmosphere.
  • Do not use the LCR40 in a humid or wet environment.
  • Do not expose the LCR40 to high temperatures or direct sunlight.
  • Do not drop the LCR40.
  • Do not disassemble the LCR40.
  • Keep the LCR40 out of the reach of children.

Before Use

  • Make sure that the LCR40 is turned off before connecting or disconnecting the probes.
  • Do not connect the probes to any component that is powered on.
  • Do not connect the probes to any component that is not rated for the voltage and current that the LCR40 can deliver.
  • Do not touch the probes when they are connected to a component.

Troubleshooting

  • If the LCR40 does not turn on, check the battery.
  • If the LCR40 displays an error message, consult the troubleshooting section of the manual.
  • If the LCR40 is not giving accurate readings, check the probes and the connections.

Maintenance

  • Keep the LCR40 clean and free of dust.
  • Do not use harsh chemicals or solvents to clean the LCR40.
  • If the LCR40 gets wet, dry it off immediately.

Warranty

The LCR40 is covered by a one-year warranty. If the LCR40 malfunctions within one year of purchase, it will be repaired or replaced free of charge.

Contact Information

Peak Electronic Design Limited Unit 10, 16-18 Enterprise Way St. Albans Hertfordshire AL4 0XU United Kingdom

Phone: +44 (0) 1727 852 277 Email: [email protected] Website: https://www.peakelec.co.uk

Additional Information

  • The LCR40 can measure the following passive components:
    • Inductors
    • Capacitors
    • Resistors
  • The LCR40 can measure the following parameters:
    • Inductance
    • Capacitance
    • Resistance
    • DC Resistance
    • Q Factor
    • Frequency
  • The LCR40 has a measurement range of:
    • Inductance: 1µH to 2H
    • Capacitance: 1pF to 100,000uF
    • Resistance: 0.5Ω to 2MΩ
  • The LCR40 uses four AAA batteries. The battery life is approximately 50 hours.
  • The LCR40 comes with a carrying case, two probes, and a user manual.

I hope this manual has been helpful. If you have any further questions, please do not hesitate to contact us.

Comments

Popular posts from this blog

Uni-t Ut70a: Full Specifications, Comparisons, Manuals, Pros And Cons, Problems, And Where To Buy